How competence is defined, assessed, authorized and re-verified for the work described on this site.
Disciplines Covered
Scheduling and quoting cover dimensional metrology disciplines: CMM performance verification and repair, portable-arm and laser tracker testing where applicable, CMM part programming, and gage calibration across hand tools, fixed gages and surface plates.

Competence Framework
Competence for each discipline is defined against the standard governing that measurement — ISO 10360-2, -5, -10 or -12 as the frame requires, or ASME B89.4.1, B89.4.10360.2 and B89.4.22 where the customer specifies them. Technical review confirms that the method applied matches the machine's probe configuration and the certificate requested before a job is scheduled. Competence is reassessed whenever a new frame type, standard revision or controller platform is added to the work accepted.
In practice our framework runs in four steps, and it runs the same way for every discipline listed above.
How Competence Is Established
- 01
Defined
Each task has a written competence requirement: the method, the equipment, the range, and the evidence that counts as proof of capability.
- 02
Assessed
Capability is demonstrated against that requirement — supervised work, witnessed measurement, and comparison against a known reference.
- 03
Authorised
Authorization is granted per task and per range, never as a blanket qualification, and it is recorded.
- 04
Re-verified
Authorizations are reviewed on a schedule and after any change of method, equipment or standard. Training records are kept for as long as the authorization is live.
Authorization and Review
Results are reviewed before release by a role separate from the one performing the test, consistent with the request-review and result-release procedures documented for this work. Certificates are issued under the performing laboratory's accredited scope, with the decision rule applied to any statement of conformity stated on the document. No certificate is released without that review step completed and recorded.
Results are reviewed before release. The review confirms that the method used matches the method quoted, that the recorded conditions are within the limits the method requires, that the calculation and the stated uncertainty are correct, and that the certificate says what the measurement supports and nothing more. Only personnel authorized for that task and range may approve the release of a result, and the approver is recorded against the certificate.
Capacity and Continuity
Scheduling spans single-machine visits through multi-stop corridor routes across Kentucky, southern Indiana and the Greater Midwest. Continuity on multi-visit contracts is maintained through the same request-review and scope-matching process used on a first-time quote, with escalation to the performing laboratory's technical staff when a result approaches a specification limit or an out-of-tolerance finding requires an impact assessment.
We staff for cover rather than for peaks. More than one person is authorized for every routine task, so absence or a spike in demand moves the schedule and leaves the result alone.
Requirements outside current authorizations are escalated, never attempted. They are quoted through a laboratory whose scope covers the measurement, or declined with the reason stated.